Round-Unarmored Plastic Cables


Flat-Unarmored Plastic Cables conductor pumpwire
Multi-conductor THHN/PVC UL listed Type TC Submersible Pump Cable
VOLTAGE:
600V
INSULATION: HIGH DIELECTRIC PVC - Polyvinyl Chloride
OUTER JACKET: PVC - Polyvinyl Chloride
SIZES: 18 AWG - 10 AWG
TEMP DRY/WET: 90°C Dry, 75°C Wet
SCOPE: Three or more conductors having TFFN or VW-1 THHN/THWN (PVC/Nylon) conductors with PVC jacket conforming to Article 318 "Cable Trays" and Article 340 "Power and Control Cable Type TC". Direct Burial. Passes 210,000 BTU flame test and suitable for use as submersible cable.
APPROVALS: UL LOGO    RoHs Logo

Flat-Unarmored Plastic pumpwire
Flexible Round 450/750 Volt TPE/TPE, H07RN-F Submersible Pump Cable
VOLTAGE:
450/750V
INSULATION: TPE - Thermoplastic Elastomer
OUTER JACKET: TPE - Thermoplastic Elastomer
SIZES: 1c 1.5mm2 - 24c 2.5mm2
TEMP DRY/WET: -40°- 90°C
SCOPE: Flexible Submersible Pump Cable designed for use in mobile service, suitable for installations where the cable must withstand medium mechanical stress, for machines in industrial and agricultural workshops, for motors and transportable machines on construction sites, for wind mills and for agricultural exploitations. Suitable for submerged installations (AD8) The use up to 1000V is accepted in fixed protected assemblies.
APPROVALS: UL LOGO    RoHs Logo


Flat-Unarmored Plastic pumpwire
2/C, 3/C & 4/C Submersible Power Cable PVC/PVC
VOLTAGE:
600
INSULATION: HIGH DIELECTRIC PVC - Polyvinyl Chloride
OUTER JACKET: PVC - Polyvinyl Chloride
SIZES: 12 AWG - 750 MCM
TEMP DRY/WET: 90°C Dry, 75°C Wet
SCOPE: Two, three or four conductors having TFFN or VW-1 THHN/THWN (PVC/Nylon) conductors with PVC jacket conforming to Article 318 “Cable Trays” and Article 340 “Power and Control Cable Type TC”. Direct Burial. Passes 210,000 BTU flame test and suitable for use as submersible cable.
APPROVALS:      RoHs Logo


Flat-Unarmored Plastic pumpwire

2/C, 3/C & 4/C Submersible Power Cable XLPE/PVC
VOLTAGE:
600V
INSULATION: XLPE - Cross-Linked Polyethlene
OUTER JACKET: PVC - Polyvinyl Chloride
SIZES: 8 AWG - 750 MCM
TEMP DRY/WET: 90°C Dry, 75°C Wet
SCOPE: Cables are listed as “sunlight resistant” and are suitable for direct burial. The cables are intended to be used in aerial applications, tray, wire-ways, troughs, channels, duct and conduit in wet or dry applications.
APPROVALS:  UL LOGO   RoHs Logo   RoHs Logo 
RoHs Logo    RoHs Logo


Flat-Unarmored Plastic pumpwire
600 Volt 3 Conductor EPR/PVC
VOLTAGE:
600V
INSULATION: EPR - Ethylene Propylene Rubber
OUTER JACKET: PVC - Polyvinyl Chloride
SIZES: 3 AWG - 500 MCM
TEMP DRY/WET: 90°C Dry, 90°C Wet
SCOPE: Round pump cable Type TC-ER suitable for use in free air, raceways or direct burials in wet or dry locations. Permitted for use in Class 1, Division 2 industrial hazardous locations per NEC.
APPROVALS:  UL LOGO   RoHs Logo   RoHs Logo 
   RoHs Logo   RoHs Logo    RoHs Logo
600V IMPACT - METHANE Pump Cable
2000 Volt 3C XLP/PVC
VOLTAGE:
2000V
INSULATION: XLPE - Cross-Linked Polyethlene
OUTER JACKET: PVC - Polyvinyl Chloride
SHIELD: Uncoated Copper Tape
SIZES: 14 AWG - 500 MCM
TEMP DRY/WET: 90°C Dry, 90°C
SCOPE: Type TC-VFD 2 kV power cable is used to supply power to submersible motors, or for connection to other power devices in industrial settings. Primary installations include cable trays, raceways and outdoor locations where supported by a messenger wire. Type TC-VFD is listed for direct burial or in underground ducts and for use in Class 1, Division 2 hazardous locations and Class 1 control circuits. This cable may be used in wet or dry locations at temperatures not to exceed 90°C.
APPROVALS:  RoHs Logo  
600V IMPACT - METHANE Pump Cable
Round Shielded 3C with Ground XLPE/PVC
VOLTAGE:
5000V
INSULATION: EPR - Ethylene Propylene Rubber
OUTER JACKET: XLPE - Cross-Linked Polyethlene
SIZES: 8 AWG - 750 MCM
TEMP DRY/WET: 90°C Dry, 75°C
SCOPE: Shielded, Medium Voltage and UL listed wet and dry locations. Suitable for use as a submersible cable. Direct Burial rated.
APPROVALS: UL LOGO  RoHs Logo  
600V IMPACT - METHANE Pump Cable
3C with Ground XLPO/XLCP
VOLTAGE:
600/1000V
INSULATION: XLPO - Cross-Linked Polyolefin
OUTER JACKET: XLCP - Cross-Linked Chlorosulfonated Polyethylene
SIZES: 16 AWG - 777 MCM
TEMP DRY/WET: 125°C
SCOPE: Round cable designed for use in deep well submersible in fresh or salt water suitable for continuous submersion to 984’ and temporary power supply where grounded circuits are not required.
Dual rated submersible Type W. Impact, Abrasion, Ozone, Sun, Weather, Heat, Oil, and Grease resistant.
APPROVALS:  UL LOGO   RoHs Logo    RoHs Logo    RoHs Logo    RoHs Logo   RoHs Logo    UL LOGO    UL LOGO   RoHs Logo