Drilling Pumpwire
Paige Pumpwire Logo

Paige Submersible Pumpwire
Flat-Unarmored Plastic Cables


Flat-Unarmored Plastic Cables conductor pumpwire
3/C with Ground THHN/PVC Power & Control Submersible Pump Cable
VOLTAGE:
600V
INSULATION: PVC - Polyvinyl Chloride
OUTER JACKET: PVC - Polyvinyl Chloride
INSULATION JACKET: Nylon
SIZES: 14 AWG - 500 MCM, 2 & 3 Conductor with ground
TEMP DRY/WET: 90°C Dry, 75°C Wet
SCOPE: Heavy Duty, (double jacketed) Flat, Submersible pump cable suitable for use within well casings
for wiring deep well fresh or salt water submersible pumps.
APPROVALS: UL LOGO    RoHs Logo


Flat-Unarmored Plastic pumpwire
3/C THHN/PVC Power & Control
Submersible Pump Cable

VOLTAGE:
600V
INSULATION: PVC - Polyvinyl Chloride
OUTER JACKET: PVC - Polyvinyl Chloride
INSULATION JACKET: Nylon
SIZES: 12 - 500 AWG, 3 Conductor
TEMP DRY/WET: 90°C Dry, 75°C Wet
SCOPE: Heavy Duty, (double jacketed) Flat, Submersible pump cable suitable for use within well casings
for wiring deep well fresh or salt water submersible pumps.
APPROVALS: UL LOGO    RoHs Logo


Flat-Unarmored Plastic pumpwire
1000 Volt 3/C no Ground XLPE/PVC
VOLTAGE:
1000
INSULATION: XLPE - Cross-Linked Polyethlene
OUTER JACKET: PVC - Polyvinyl Chloride
SIZES: 8 AWG - 2 AWG
TEMP DRY/WET: 90°C Dry, 75°C Wet
SCOPE: 1000 volt, Heavy Duty Flat pump cable three conductors without ground suitable for use within well casings for wiring deep well fresh or salt water submersible pumps.
APPROVALS:  RoHs Logo   RoHs Logo   RoHs Logo


Flat-Unarmored Plastic pumpwire

3/C with Ground Tested Good for 2.4kV per NEC XLPE/PVC Submersible Pump Cable
VOLTAGE:
5000V
INSULATION: XLPE - Cross-Linked Polyethlene
OUTER JACKET: PVC - Polyvinyl Chloride
SIZES: 6 AWG - 2/0
TEMP DRY/WET: 90°C Dry, 90°C Wet
SCOPE: Flat 5000v submersible pump cable with cross-linked XLPE insulated circuit and grounding conductors and an overall PVC jacket. Tested and rated for up to 2.4kV per NEC. Suitable for use within well casings for wiring deep-well submersible water pumps.
APPROVALS:  UL LOGO    RoHs Logo


600V IMPACT - METHANE Pump Cable
600 Volt 3/C with Ground THHN/HDPE
VOLTAGE:
600V
INSULATION: PVC - Polyvinyl Chloride
INSULATION JACKET: Nylon
OUTER JACKET: HDPE High Density Polyethylene
SIZES: 10 AWG - 4 AWG
SCOPE: Cable is designed for extra hard duty use in Methane mines where flexibility and the toughness of armor is needed. The jacket, made with an extra hard duty, abrasion and impact resistant compound, minimizes potential damage and stops gas from migrating in the first place. Tight construction minimizes potential gas migration should the jacket be damaged. The cable is rated for use in Deep Well Submersible Methane Gas Applications at temperatures not to exceed 75°C Wet.
APPROVALS:  UL LOGO    RoHs Logo
600V IMPACT - METHANE Pump Cable
2/C & 3/C CONDUCTOR with or without Ground PVC/PVC
VOLTAGE:
600V
INSULATION: PVC - Polyvinyl Chloride
OUTER JACKET: HDPE High Density Polyethylene
SIZES: 14 AWG - 6 AWG
TEMP DRY/WET: 60°C
SCOPE: Direct Burial Underground feeder cable with or without ground and a sunlight-resistant PVC overall jacket.
APPROVALS:  UL LOGO    RoHs Logo